The Alfa Laval control and check valves are highly reliable valves used to ensure single directional product flow through process lines. This provides protection for process equipment that can be affected by reverse flow and prevents pressure surges and/or system shutdown.

Alfa Laval Valve Automations: Indication Unit, IndiTop, ThinkTop, ThinkTop Basic, ThinkTop D30, GreenTop

 

DescriptionFeaturesHow It WorksDetailsDocumentation

LKC-2 Non-return Valve

Specially designed for use in stainless steel pipe installations, LKC-2 non-return valves prevent the reverse flow of fluids. Widely used in various processes throughout the sanitary industry, these standard non-return valves are safe and highly reliable.

Related Industries:

Food and beverage, Home and Personal care

 

Safe and reliable process protection

Alfa Laval LKC-2 non-return valves are highly reliable check valves ensure single directional product flow through process lines. This provides protection for process equipment that can be affected by reverse flow and prevents pressure surges and/or system shutdown.

Non-return valve range

The standard range of Alfa Laval LKC-2 non-return valves are constructed of standard 304 or acid-resistant 316L stainless steel. Easy to install, the valves are designed to handle maximum product pressure up to 10 bar and temperatures ranging from -10°C to 140°C (EPDM). For added versatility, these check valves are available with either a semi-bright or polished finish, and a variety of welding ends for ISO or DIN connections.

 

Construction

The Alfa Laval LKC-2 non-return valve consists of an upper valve body, lower valve body, valve plug, seal ring, and guide disc. The valve body is assembled by means of a clamp and hygienically sealed with a special seal ring. A guide disc and four legs guide the spring-loaded valve plug with an O-ring seal. LKC-2 has welding ends for ISO or DIN connections.

Working principle

The spring acts on the valve plug, keeping the valve closed until the force from the pressure in the inlet exceeds the force of the spring. If a reverse flow should occur, the spring force and the pressure from the outlet will keep the valve closed.

Options

  • Product wetted seal rings in NBR or FPM

Product Benefits

  • Highly reliable
  • Easy to install
  • Protection for process equipment

 

 

1 = Flow direction.

Shows the optimal built-in situation to ensure the valve is drainable. The four guide legs of the valve cone ensure good alignment. 90° rotation.

Concept

Non-return valve LKC-2 is designed for use in stainless steel pipe
installations to prevent reverse flow.

Working principle

LKC-2 opens when the pressure below the valve plug exceeds the
pressure above the plug and the spring force.
The valve closes when pressure equalization has been achieved. A
higher counter pressure will press the valve plug against the seat.

Standard Design

The valve body is in two parts, assembled by means of a clamp ring
and hygienically sealed with a special seal ring. A guide disc and four
legs guide the spring loaded valve plug with an O-ring seal.
The valve is available with welding ends for tubes according to ISO
and DIN 11850.

TECHNICAL DATA
Temperature
Max. temperature: . . . . . . . . . . . . . 140°C (EPDM)
Min. temperature: . . . . . . . . . . . . . . -10°C

Pressure
Max. product pressure: . . . . . . . . . . 1000 kPa (10 bar)

Mechanical
Required differential pressure for opening the valve when fitted in a
vertical pipe, as shown in fig. 3, is approx. 6 kPa (0.06 bar)

 

PHYSICAL DATA
Materials
Product wetted steel parts: . . . . . . . . 1.4301 (304) / 1.4404 (316L)
External surface finish . . . . . . . . . . . Semi-bright (blasted)
Internal surface finish . . . . . . . . . . . . Bright (polished), Ra < 0.8 µm
Product wetted seals: . . . . . . . . . . . EPDM rubber

Options
Product wetted seal rings of Nitrile (NBR) or Fluorinated rubber (FPM).

DescriptionFeaturesHow It WorksDetailsDocumentation

LKC UltraPure Non-return Valve

Designed to meet the specific demands of the biotech, pharmaceutical and personal care industries, the LKC UltraPure non-return valve provide safe, easy installation and high, consistent quality.

Related Industries:

Biotech and Pharmaceuticals, Food and beverage

 

UltraPure quality

LKC UltraPure is developed to facilitate safe and easy installation that ensures optimum integrity. This valve offer high and consistent quality and thorough documentation which meet the strict standards of the biotech, pharmaceutical and personal care industries.

High and consistent quality

LKC UltraPure valves are subject to rigorous quality control. Alfa Laval performs all incoming and outgoing quality control and inspections and closely monitors every aspect of the manufacturing process – ­ from raw material sourcing to tolerance and surface finish inspection to packaging and labelling. Tolerances and all surface finishes, for instance, are inspected with calibrated equipment. This helps ensure the highest quality possible.

Completely documented

All equipment and components in the Tri-Clover UltraPure portfolio are supplied with Alfa Laval Q-doc, a comprehensive documentation package that provides full transparency of the entire supply chain, from raw material to final equipment delivery. This smoothes purchasing and installation procedures as well as facilitates qualification, validation and change control procedures. Based on GDP (Good Documentation Practice), Alfa Laval Q-doc covers every aspect of UltraPure equipment supply and provides customers with  transparent and well-documented quality assurance of the sourced equipment.

The Q-doc package for LKC UltraPure comprises quality and manufacturing procedures, material certificates and full traceability. This attention to detail maximizes uptime and minimizes risk.

 

How it works

Application

Tri-Clover® LKC UltraPure is a non-return valve preventing reverse flow in a system. The UltraPure execution is designed and documented to meet the demand in industries like BioPharm and Personal Care.

Working principle

The spring acts on the valve plug and keep the valve closed until the force from the pressure in the inlet exceeds the force of the spring. If a reverse flow should occur the spring force and the pressure from the outlet will keep the valve closed.

Standard Design

The valve body is made in two parts that are assembled with a clamp ring. A guide disc and four legs guide the spring loaded valve plug in the valve body.

 

 

 

 

1 = Flow direction.

Shows the optimal built-in situation to make sure the valve is drainable. The four guide legs of the valve cone ensures good alignment.

90° rotation

Concept
LKC is a non-return valve preventing reverse flow in a system. The
UltraPure execution is designed and documented to meet the demand
in industries like BioPharm and Personal Care.

Working principle
The spring acts on the valve plug and keeps the valve closed until the
force from the pressure in the inlet exceeds the force of the spring. If a
reverse flow should occur the spring force and the pressure from the
outlet will keep the valve closed.

Standard Design
The valve body is made in two parts that are assembled with a clamp
ring. A guide disc and four legs guide the spring loaded valve plug in
the valve body.

TECHNICAL DATA
Max. product pressure: . . . . . 1000 kPa (10 bar)
Required differential pressure for opening the valve when fitted in a
vertical pipe, as shown in fig. 2, is approx. 6 kPa (0.06 bar).

[/one_half]

PHYSICAL DATA
Product wetted steel part . . . .1.4404 (316L) Acc. to EN 10088 or equal (AISI 316L)
Other steel parts . . . . . . . . . .1.4301 (304) Acc. to AISI 304
Spring . . . . . . . . . . . . . . . .Electropolished

Elastomers
Product wetted elastomer . . . .EPDM Acc. to FDA and USP Class VI
Temperature: -10°C – 140°C
Product wetted elastomer . . . .FPM Acc. to FDA
Temperature: -10°C – 180°C

Surface specification (Product wetted steel parts)
Alfa Laval designation 7 . . . . .Internal: Ra < 0.8 µm ASME BPE designation: SF3
External: Ra < 0.8 µm
Alfa Laval designation PL . . . .Internal: Ra < 0.5 µm
ASME BPE designation: SF1
External: Ra < 0.8 µm

Connections
Weld ends . . . . . . . . . . . . . .Matching tubes and fittings: ISO 2037/ Series A/DIN Acc. to ISO or DIN
Clamp ends . . . . . . . . . . . . .Matching tubes and fittings: ISO 2037/ Series A/DIN Acc. to ISO or DIN

DescriptionDetailsTechnical Data

LKC-2 SPRING CHECK VALVE

ABS offers the LKC-2 disc-style spring check valve from Alfa Laval. The LKC-2 valve is designed for use in stainless steel pipe installations to ensure process integrity by preventing the reverse flow of fluids. This protects your process equipment that could be affected by reverse flow and prevents pressure surges and system shutdown. Styles are available for vertical or horizontal mounting.

MODELS

  • Vertical
  • Horizontal
[on e_half last=”yes”]

Related Industries:

Processed Foods, Beverages, Brewery, Home & Personal Care, Chemical

[/one_half]

WORKING PRINCIPLE

The LKC-2 opens when the pressure below the valve plug exceeds the combination of product and spring pressure above the plug. The valve closes when the combination of product and spring pressure above the valve plug exceeds the pressure below the plug.

STANDARD DESIGN

The valve body is in two parts, assembled by means of a sanitary clamp and sealed with a special seal ring. A guide disc and four legs guide the spring loaded valve plug with an o-ring seal. LKC-2 has welding ends or Tri-Clamp® connections.

When horizontal installation is necessary, choose the horizontal model to ensure proper drainability.

MATERIALS

Steel Parts 304, 316L
Seal Rings EPDM rubber (standard)
Fluorinated rubber (optional)
Finish ?32 Ra
Electropolished spring

TECHNICAL DATA

Product Pressure (max) 145 psi
Temperature (max) 284°F (EPDM)
Temperature (min) 14°F
Connections Tri-Clamp, Weld

Required differential pressure for opening the valve when fitted in a vertical pipe is approximately 0.87 psi.

 

VERTICAL DIMENSIONS

OD(in) A(in) A Tri-Clamp(in) ID(in) t(in) H(in) Weight(lb)
1 2.46 4.12 0.89 0.06 3.23 1.1
2.95 4.61 1.4 0.06 3.75 1.5
2 3.44 5.10 1.91 0.06 4.29 2.2
3.74 5.40 2.38 0.07 5.39 3.8
3 4.53 6.19 2.83 0.09 5.83 5.3
4 6.10 7.76 3.84 0.09 6.46 9.5

 

HORIZONTAL DIMENSIONS

 

 

 

 

OD(in) A(in) A Tri-Clamp(in) C(in) ID(in) t(in) H(in) Weight(lb)
1 3.76 5.38 0.34 0.89 0.06 3.23 1.1
3.41 5.13 0.4 1.4 0.06 3.75 1.5
2 4.17 5.8 0.41 1.91 0.06 4.29 2.2
4.81 6.3 0.53 2.38 0.07 5.39 3.8
3 5.69 7.31 0.65 2.83 0.09 5.83 5.3

 

DescriptionDetails

45BYMP Y-BODY BALL CHECK VALVE

ABS offers the original sanitary Y-body check valve—Alfa Laval’s 45BYMP ball check valve. This valve provides backflow prevention for stainless steel process lines. Its simple, robust design delivers years of reliable service.

With a sanitary design and low pressure drop, the 45BYMP has been a trusted option for years. The valve meets 3-A sanitary standards and can be mounted either vertically or horizontally.

Related Industries:

Processed Foods, Dairy, Beverages, Brewery, Home & Personal Care, Chemical

APPLICATIONS

The 45BYMP ball check valve operates at a wide range of pressures and flow rates. Because the sealing check ball moves completely out of the process flow when open, the valve offer low pressure reduction and handles viscous liquids or liquids containing solid particles easily. Alfa Laval’s 45BYMP is authorized to carry the 3-A symbol.

WORKING PRINCIPLE

When liquid under normal pressure enters the inlet of the 45BYMP check valve, an elastomeric ball is pushed upward into the “Y” branch (lower pressure area) of the valve. When the liquid flow stops, the pressure within the valve equalizes, and the ball returns from the “Y” branch of the valve and rests itself against the smaller diameter of the valve near its inlet. Should a reverse flow situation occur, the opposing pressure of the fluid will seat the ball firmly against the inlet of the valve, preventing reverse flow. The valve operates in both a vertical or horizontal orientation.

STANDARD DESIGN

The valve consists of a single-piece, stainless steel body with an elastomeric ball (see materials table for options). The “Y” branch of the valve maintains a Tri-Clamp® connection along with an associated Tri-Clamp, end-cap, and NBR gasket. The valve is polished internally and externally to meet or exceed 3-A sanitary standards.

MATERIALS
Product Wetted Steel Parts 316L
Other Steel Parts 304
Ball Buna, EPDM, SFY, Nylon (max 140°F)
Gasket NBR (standard)
Finish 32 Ra (standard)
TECHNICAL DATA
Size 1 1/2 – 3 inch
Connections Tri-Clamp, weld
Max Product Pressure 200 psi
Min Product Pressure 1 psi
Temperature Range Based on elastomer choice

 

DescriptionFeaturesDetails

TRI-CLOVER® 62-174/326 AIR BLOW CHECK VALVE

Air blow check valves protect pipelines against corrosion by air-drying the line. Air-drying causes a protective oxide film to form, and this film is the key to placing a system in its most corrosion-resistant condition.

ABS offers the Tri-Clover® 62-174/326 air blow check valve from Alfa Laval. These valves are designed to evacuate lines of product or clean-in-place (CIP) solution, and they are also used for air agitation of product in tanks and other vessels to thoroughly mix and blend the product. The Tri-Clamp®connection makes this valve easy to disassemble and reassemble for cleaning, replacing filter media, or inspection.

MODELS

  • 62-174 (low volume)
  • 62-326 (high volume)

Related Industries:

Processed Foods, Dairy, Beverages, Brewery, Home & Personal Care, Chemical

 

FEATURES
  • Fail-safe operation – Simple air-to-open, spring-to-close operation prevents product or CIP solution back flow.
  • Easy assembly & disassembly – Tri-Clamp connections permit quick assembly and disassembly for replacing filter media, cleaning, or inspection.
  • Remotely controlled – The supply of air to valve remotely controls the valve.
  • Rugged construction – The standard material is 316 stainless steel. The spherical plug assembly is bonded EPDM rubber.
  • 3-A conformance – For applications requiring a final filtering of air prior to entering a tank or pipelines, the valve conforms to 3-A accepted practices.
APPLICATIONS

Alfa Laval’s Tri-Clover® 62-174/326 air blow check valves are designed to perform two main functions:

  1. To evacuate lines of product or CIP solution
  2. For air agitation of product in tanks and other vessels to thoroughly mix and blend the product
WORKING PRINCIPLE

Filtered air enters the adapter (A) and exerts pressure on the valve plug assembly (B), causing it to move forward and unseat. The filtered air passes through the valve and around the valve plug assembly (B), entering the pipeline or tank.

When the air pressure entering the adapter (A) is shut off, the valve plug assembly is returned to its normally closed position by return spring, preventing any product or CIP solution back flow.

STANDARD DESIGN

The air blow check valve can be used in any position: horizontal or vertical. The valve can be used for product agitation in tanks or other vessels by using a Tri-Clamp, gasket, and mounting ferrule. No other fittings are required.

To use the air blow check valve to evacuate the lines of product or CIP solution, it’s recommended to clamp it on the end of the “Y” branch of a ball check valve, rather than install it in the line.

FEATURES
  • Fail-safe operation – Simple air-to-open, spring-to-close operation prevents product or CIP solution back flow.
  • Easy assembly & disassembly – Tri-Clamp connections permit quick assembly and disassembly for replacing filter media, cleaning, or inspection.
  • Remotely controlled – The supply of air to valve remotely controls the valve.
  • Rugged construction – The standard material is 316 stainless steel. The spherical plug assembly is bonded EPDM rubber.
  • 3-A conformance – For applications requiring a final filtering of air prior to entering a tank or pipelines, the valve conforms to 3-A accepted practices.
MATERIALS
Product Wetted Steel Parts 316
Product Wetted Parts EPDM (standard), SFY
Other Steel Parts 304
Other Seals Buna
TECHNICAL DATA
Pressure Range Varies based on style of clamp used. Contact CSI.
Temperature Range 20 – 284°F
Min Air Pressure 8 – 10 psi
ADAPTER OPTIONS

A variety of adapters are available for connecting to your air line.

AIR BLOW FILTER CAPACITY TEST